Pipe Fittings for Water Treatment and Desalination
Desalination puts two stresses on a piping system at once: high chloride concentration and, in the reverse osmosis train, high pressure. That combination is what rules out 316L in many positions and makes duplex stainless the usual specification for the seawater side.
Where the material decisions are made
| System area | Typical material | Why |
|---|---|---|
| Seawater intake and outfall | Duplex 2205, super duplex 2507, GRP | Chlorides at velocity; erosion and pitting resistance |
| Pre-treatment and filtration | Duplex 2205, 316L | Chloride pitting under deposits |
| SWRO high pressure train | Super duplex 2507, 316L (low Cl), 904L | High pressure plus chloride; PREN above 40 common |
| Permeate and post-treatment | 316L, 304L | Low chloride, cleanliness matters |
| Brine discharge | Super duplex 2507 | Highest chloride, highest temperature |
Why 316L often fails here
316L relies on a molybdenum addition for pitting resistance and reaches a PREN of roughly 25. Seawater at temperature, with chlorides above about 500 mg/l in a stagnant or deposit-covered area, can exceed that. Duplex 2205 reaches a PREN of about 34-36 and adds a much higher yield strength; super duplex 2507 reaches about 42-43 for the hottest and most concentrated brine.
High pressure considerations
- The SWRO membrane train runs at high pressure – wall thickness and fitting rating must be checked, not assumed
- Cyclic pressure means fatigue: smooth internal transitions and full penetration welds matter
- Flange joints in the high pressure train are usually RTJ or specially gasketed
- Support spacing follows the higher strength of duplex, which can reduce steel weight
What we supply
- ASME B16.9 elbows, tees, reducers and caps in duplex 2205 / 2507 and 304L / 316L
- ASME B16.5 flanges in matching grades, plus EN 1092-1 plate flanges
- Stub ends and lap joint assemblies for pump and skid connections
- Pipe bends to drawing for intake and outfall layouts
Documents
- EN 10204 3.1 certificate with chemistry, mechanicals and PREN where requested
- Ferrite content report for duplex (typically 35-65%)
- Corrosion test reports (ASTM G48 / A923) on request
- Third party inspection to the project specification
Frequently asked questions
Can 316L be used in the RO high pressure train?
Sometimes, where the chloride level and temperature are low enough and the design allows it. In most seawater RO plants the high pressure side is duplex or super duplex. The decision should follow the chloride concentration, temperature and the specified PREN.
Do you supply fittings to EN standards for European projects?
Yes – EN 10253 dimensions and EN 1092-1 flanges are both available, so a European-designed plant can be supplied without ASME substitutes.
Is duplex suitable for buried seawater lines?
It can be, subject to external corrosion protection and cathodic protection design. Buried service adds external corrosion conditions that should be reviewed with the pipeline design, not only the internal fluid.
Send the chloride level, temperature, pressure and required material – we will confirm the grade. Request a quotation · info@pipingfitting.com