Low Temperature Pipe Fittings | A420 WPL6 & A350 LF2 Impact Tested

Low Temperature Pipe Fittings: ASTM A420 WPL6 and A350 LF2

Below about -29°C ordinary carbon steel becomes brittle: a carbon steel elbow that is ductile at ambient temperature can fracture without deformation in a cold line. Low temperature fittings are specified for that reason, and the Charpy impact test is the evidence that the material is suitable for the design metal temperature.

Grades for low temperature service

Grade Product form Standard C max Mn Si Tensile Yield Impact test
WPL6 Fittings (elbows, tees, reducers, caps) ASTM A420 0.30 0.60-1.35 0.15-0.30 415-585 MPa 240 MPa -45°C, 18 J average typical
A350 LF2 Forged flanges and forged fittings ASTM A350 0.30 0.60-1.35 0.15-0.30 485-655 MPa 250 MPa -46°C
A350 LF3 Forged flanges ASTM A350 0.20 0.90 max 0.20-0.35 485-655 MPa 260 MPa -101°C
A420 WPL3 Fittings ASTM A420 0.20 0.31-0.64 0.13-0.37 415-585 MPa 240 MPa -101°C

What the impact test actually proves

The Charpy test measures the energy absorbed by a notched specimen struck at the specified temperature. It is performed on the heat, not on the finished fitting, so the certificate you receive documents the material – confirm that the test temperature on the certificate is at or below your design metal temperature, and that the test was taken from a representative section.

Where low temperature fittings are used

  • LNG and cryogenic piping, cold boxes and loading arms
  • LPG, propane and butane storage and transfer
  • Refrigeration plants and cold storage
  • Ammonia and CO2 process systems
  • Cold climate pipelines in northern Canada, Russia and northern China
  • Nitrogen, oxygen and argon distribution systems

Manufacturing notes

  • Fully killed fine grain steel is required – the certificate shows the deoxidation practice and the grain size
  • Normalising is specified where the order requires it, particularly for heavy sections
  • Hardness limits can be applied for sour or wet service together with the impact requirement
  • Marking includes the grade, heat number and, where requested, the impact test temperature

Custom sizes, grades and marking

  • We make these fittings to order rather than only from a catalogue: non-standard sizes, heavier wall, special centre-to-end dimensions and prepared ends to the drawing.
  • Marking and documentation are agreed at the quotation stage – heat number, size and schedule stamps, your own brand mark, and EN 10204 3.1 mill test certificates with the shipment.
  • Where a project needs a grade that is not held in stock, tell us the service condition and the applicable standard; we will confirm what can be produced and the lead time before the order is placed.

Frequently asked questions

Can I use A234 WPB below -29°C?

Not for a design metal temperature below the impact test exemption allowed by the applicable code. For cold service the fitting should be ordered as an impact tested grade – A420 WPL6 for fittings, A350 LF2 for flanges – and the certificate must show the impact test at or below the design temperature.

Do you supply the Charpy test report with the fittings?

Yes. The impact test result appears on the material certificate. Specify the test temperature and the acceptance criteria on the order; where a third party has to witness the test we coordinate that before production.

Are A350 LF2 flanges dimensionally different from A105 flanges?

No – the dimensions follow the same ASME B16.5 tables. The difference is the material, the impact testing and frequently the normalising condition.

Send the design metal temperature, grade and size – we will confirm the impact test route and documents. Send the specification for a quotation · info@pipingfitting.com

Related pages