LNG and Cryogenic Pipe Fittings for Service Down to -196°C
Cryogenic service is defined by one thing: the material has to remain ductile at the operating temperature. At -196°C, ordinary carbon steel behaves like glass. Fittings for LNG, nitrogen, oxygen and cold box service are therefore selected by impact tested material and by the fabrication details that keep that toughness intact.
Material selection by temperature
| Service temperature | Typical material | Note |
|---|---|---|
| Down to -46°C | A420 WPL6 fittings, A350 LF2 flanges | Impact tested carbon steel for LPG and cold climate |
| Down to -101°C | A420 WPL3, A350 LF3, 3.5% nickel steel | Ethylene and some process cold service |
| Down to -196°C | 304L / 316L austenitic stainless (and 9% nickel for some tanks) | LNG, nitrogen, argon; austenitic stainless does not have a ductile-brittle transition |
| Below -196°C | Special alloys – aluminium, Invar, austenitic stainless | Helium and hydrogen liquefaction, specialist terminals |
Why 304L for LNG
Austenitic stainless steel does not show the sharp ductile-to-brittle transition of carbon steel: its toughness falls gradually and remains adequate at LNG temperature. The low carbon grade 304L is preferred because it avoids sensitisation around welds, which matters on thin wall pipe that cannot be solution annealed after fabrication.
Fabrication details that decide the outcome
- Welding procedure qualified at the service temperature, with impact testing of the procedure test pieces
- Clean, dry purging of the root – moisture and grease become a safety issue in oxygen and LNG service
- No field bending or flame straightening of cryogenic spools
- Support design allowing for the large thermal contraction between ambient and operating temperature
- Specify whether the fitting is to be supplied in the solution annealed condition
What we supply
- ASME B16.9 elbows, tees, reducers and caps in 304L / 316L and in A420 WPL6
- Flanges to ASME B16.5 in matching grades, with RTJ facing where the specification requires it
- Stub ends and lap joint assemblies for lines that are dismantled for inspection
- Pipe bends to drawing for cold box layouts
Documents for cryogenic service
- EN 10204 3.1 mill test certificate with impact test results
- Heat number marking traceable to the certificate
- Welding procedure and procedure qualification records where fabrication is in scope
- Third party inspection and witness of impact testing on request
Custom sizes, grades and marking
- Non-standard sizes, heavy wall and bends to drawing.
- Marking includes grade, heat number and the service designation where required.
- Documentation packages can be compiled to the terminal specification.
Frequently asked questions
Can A350 LF2 be used for LNG?
Not for the LNG temperature itself (-162°C). A350 LF2 is impact tested to about -46°C. For LNG the line is normally 304L stainless or 9% nickel steel, depending on the design.
Do you supply cryogenic fittings with impact tests at -196°C?
For austenitic stainless the specification usually calls for lateral expansion or absorbed energy testing at the service temperature. State the test temperature and acceptance criteria, and whether the test is on the base material or on a welded procedure test piece.
Are your fittings suitable for oxygen service?
Oxygen service adds cleanliness requirements – degreasing, cap protection and a documented cleaning procedure – on top of material selection. Tell us it is oxygen service so the cleaning route is agreed before manufacture.
Send the design temperature, service and material specification – we will confirm the test route. Request a quotation · info@pipingfitting.com