Pulp & Paper Pipe Fittings | Duplex for White Liquor Service

Pipe Fittings for Pulp and Paper Mills

Pulp mill piping is a corrosion problem before it is a pressure problem. White liquor, black liquor, chlorine dioxide and hot caustic attack different materials in different ways, and the grade that survives one area often fails in the next.

Service areas and material choice

Area Aggressive condition Typical material
White liquor / green liquor Hot alkaline, scaling, erosion Duplex 2205, 316L
Digester and blow lines High temperature alkaline 316L, duplex 2205
Black liquor Alkaline with solids, erosion 316L, duplex
Bleach plant (chlorine dioxide) Strong oxidiser, chlorides Super duplex 2507, 904L, nickel alloys
Chlorine / hypochlorite Wet chlorine Hastelloy C276, titanium
Paper machine white water Low chloride, cleanliness 304L, 316L

Why duplex is common in the liquor circuit

White liquor combines hot alkali with abrasive solids and chloride contamination from the wood and the process. Duplex 2205 gives higher resistance to chloride stress corrosion cracking than 316L at a yield strength that also resists erosion, which is why it has become the default in many liquor lines.

Fabrication details that matter

  • Stress corrosion cracking in hot alkaline service is controlled by stress relief and by weld quality, not only by grade
  • Chloride contamination from cleaning chemicals can cause pitting in stainless that was correct at design
  • Dead legs and low points accumulate solids – layout matters as much as material
  • Duplex requires ferrite balance control and pickling after welding

What we supply

  • ASME B16.9 fittings in 304L / 316L, duplex 2205 and super duplex 2507
  • Flanges to ASME B16.5 and EN 1092-1 in matching grades
  • Stub ends for lines dismantled during shutdowns
  • Pipe bends and custom-shaped fittings to drawing

Documents

  • EN 10204 3.1 certificate with chemistry and mechanicals
  • Ferrite content report for duplex items
  • Pickling and passivation confirmation
  • Third party inspection on request

Frequently asked questions

Can 316L be used in the bleach plant?

Rarely for chlorine dioxide or hypochlorite; those services typically require super duplex, 904L or a nickel alloy. 316L is more common in the paper machine and white water circuits where chloride levels are low.

Do you supply fittings with a mill finish suitable for pulp service?

Fittings are supplied pickled and passivated as standard. Where a specific internal finish is required, state the requirement so the finishing route is agreed.

Are duplex fittings available in the larger sizes used on blow lines?

Yes – large diameter duplex fittings are made to order, sometimes as fabricated items where a seamless fitting is not available in the required size.

Send the service, temperature and chloride level – we will confirm the material. Request a quotation · info@pipingfitting.com